MBS1250 063G1857 30B0506 Hydraulic Pressure Sensor Transmitter 0-400 Bar 4-20mA for Excavator | JISION
Product Description MBS1250 063G1857 30B0506 Hydraulic Pressure Sensor Transmitter for Excavator & Construction Machinery Product Model: MBS1250 Reference Part Numbers: 063G1857 / 30B0506 Pressure Range: 0–400 Bar Output Signal: 4–20 mA Supply Voltage: 8–30V DC Brand: JISION Product Overview The ...
hydraulic pressure sensor 0-400 bar
,4-20mA excavator pressure transmitter
,MBS1250 hydraulic sensor transmitter
Product Description
MBS1250 063G1857 30B0506 Hydraulic Pressure Sensor Transmitter for Excavator & Construction Machinery
Product Model: MBS1250
Reference Part Numbers: 063G1857 / 30B0506
Pressure Range: 0–400 Bar
Output Signal: 4–20 mA
Supply Voltage: 8–30V DC
Brand: JISION
Product Overview
The JISION MBS1250 063G1857 30B0506 Hydraulic Pressure Sensor Transmitter is a replacement pressure measurement component offered for compatible excavators, construction machinery, and industrial hydraulic applications.
Based on the Danfoss MBS1250 pressure transmitter series, this sensor is designed to measure fluid pressure and convert it into a proportional electrical current signal for compatible electronic monitoring and control systems.
The illustrated pressure transmitter features a silver-colored metal housing, red identification label, black electrical connector, hexagonal mounting section, and threaded pressure connection protected by a blue plastic cap.
The specified 0–400 bar measurement range and 4–20 mA output make this configuration suitable for compatible high-pressure hydraulic monitoring applications.
With an 8–30V DC supply voltage, the transmitter can be integrated into an electronic control system that supports the corresponding voltage, current signal, and connection specifications.
The MBS1250 pressure transmitter is intended for pressure measurement applications where accurate matching of the original sensor's pressure range, electrical output, connector, and mounting specifications is required.
JISION supplies aftermarket pressure sensors, hydraulic solenoid valves, excavator wiring harnesses, hydraulic pump components, and construction machinery replacement parts to equipment maintenance workshops, international distributors, and wholesale customers.
Product Specifications
| Item | Description |
|---|---|
| Brand | JISION |
| Product Name | Hydraulic Pressure Sensor Transmitter |
| Product Series | MBS1250 |
| Reference Part Number | 063G1857 |
| Additional Reference | 30B0506 |
| Referenced Sensor Manufacturer | Danfoss |
| Product Category | Hydraulic Pressure Sensors |
| Pressure Range | 0–400 Bar |
| Pressure Range in MPa | 0–40 MPa |
| Output Signal | 4–20 mA |
| Supply Voltage | 8–30V DC |
| Sensor Type | Electronic Pressure Transmitter |
| Housing | Metal |
| Housing Color | Silver |
| Electrical Connector | Black Molded Connector |
| Connector Contacts | 4 Visible Pins |
| Installation Feature | Hexagonal Mounting Section |
| Pressure Connection | Threaded Metal Port |
| Protective Cap | Blue Plastic Cap |
| Application | Hydraulic Pressure Measurement |
| Compatible Equipment | Selected Excavators and Hydraulic Machinery |
| Condition | New |
| Replacement Type | Aftermarket Replacement |
| Supply Type | Individual / Wholesale Supply |
Key Features & Benefits
1. 0–400 Bar Pressure Measurement Range
The MBS1250 pressure transmitter is specified for pressure measurement within a nominal range of 0–400 bar.
This configuration can be used in compatible high-pressure hydraulic systems where the selected sensor range matches the equipment's operating and monitoring requirements.
2. Standard 4–20 mA Current Output
The sensor converts pressure measurements into an electrical current signal.
The 4–20 mA output format supports integration with compatible electronic controllers, monitoring systems, and industrial pressure measurement equipment.
3. 8–30V DC Power Supply
The listed configuration supports an 8–30V DC supply range.
The connected equipment must provide the correct power supply and use an input circuit compatible with the sensor's current output.
4. Metal Sensor Housing
The illustrated product uses a cylindrical metal housing designed to protect the internal sensing components.
Its compact construction is suitable for installation in compatible construction machinery and industrial hydraulic systems.
5. Integrated Electrical Connector
The black molded connector provides an interface for the equipment wiring harness.
Correct terminal assignment and electrical wiring are essential for proper pressure measurement and sensor operation.
6. Threaded Pressure Connection
The sensor features a threaded pressure connection with a hexagonal wrenching section.
The illustrated blue protective cap helps protect the pressure port from contamination during storage and handling.
The cap must be removed before installation.
7. Practical Replacement Solution
The MBS1250 063G1857 pressure transmitter is offered for compatible hydraulic system maintenance and replacement applications.
Customers should verify the complete original sensor specifications before ordering.
Product Applications
The MBS1250 Hydraulic Pressure Transmitter can be considered for compatible hydraulic pressure measurement applications, including:
-
Excavator Hydraulic Pressure Monitoring
-
Construction Machinery Hydraulic Systems
-
Hydraulic Pump Pressure Measurement
-
Industrial Hydraulic Power Units
-
Heavy Equipment Pressure Monitoring
-
Hydraulic System Maintenance and Diagnostics
-
Compatible Electronic Control Systems
-
Industrial Pressure Measurement Equipment
Important: The specific equipment application depends on the original pressure sensor specification and the machine's electrical and hydraulic system configuration.
Compatible Equipment & Part Number Information
Sensor Series: Danfoss MBS1250
Referenced Part Numbers:
-
063G1857
-
30B0506
Pressure Rating: 0–400 Bar
Electrical Output: 4–20 mA
Supply Voltage: 8–30V DC
Compatibility Notice
Not every MBS1250 pressure transmitter uses the same pressure range, electrical connector, output signal, or mounting configuration.
Before purchasing, please verify:
-
Original Sensor Part Number
-
Equipment Brand and Model
-
Pressure Measurement Range
-
Supply Voltage
-
Output Signal
-
Connector Type and Pin Configuration
-
Pressure Port Thread Size
-
Sealing Method
-
Sensor Installation Dimensions
The reference number 30B0506 should be checked against the original product documentation to confirm whether it identifies the same configuration as 063G1857.
Common Pressure Sensor Failure Symptoms
A faulty hydraulic pressure transmitter may contribute to:
-
Incorrect Hydraulic Pressure Readings
-
Unstable Pressure Signal Output
-
Missing 4–20 mA Signal
-
Pressure Sensor Fault Codes
-
Damaged Electrical Connector Pins
-
Sensor Supply Voltage Problems
-
Fluid Leakage Around the Pressure Connection
-
Intermittent Pressure Monitoring
These symptoms may also result from damaged wiring, insufficient electrical supply, hydraulic pressure problems, or controller faults.
Proper diagnosis should be performed before replacing the pressure sensor.
Why Choose JISION?
Professional Construction Machinery Spare Parts Supplier
JISION focuses on supplying aftermarket replacement components for excavators, diesel engines, hydraulic systems, and construction machinery.
Wide Product Selection
Our product range includes:
-
Hydraulic Pressure Sensors
-
Pressure Transmitters
-
Oil Pressure Switches
-
Hydraulic Solenoid Valves
-
Hydraulic Pump Components
-
Excavator Wiring Harnesses
-
Excavator ECU & ECM Controllers
-
Excavator Monitor Displays
-
Diesel Engine Sensors
-
Construction Machinery Electrical Parts
Wholesale & Distributor Support
JISION welcomes inquiries from construction machinery spare parts distributors, hydraulic repair workshops, machinery maintenance providers, and international wholesale buyers.
Part Number Matching Assistance
Our team can assist with identifying replacement parts using original sensor model numbers, product photographs, equipment information, and technical specifications.
International Supply Service
We provide product sourcing assistance, quotations, and export order support for construction machinery replacement parts buyers worldwide.
Installation & Maintenance Recommendations
-
Verify the original pressure sensor part number and technical specifications.
-
Confirm the 0–400 bar measurement range and 4–20 mA output requirement.
-
Check the 8–30V DC supply compatibility.
-
Verify the electrical connector pin assignments.
-
Confirm the pressure port thread and sealing specifications.
-
Shut down the equipment and release residual hydraulic pressure following the manufacturer's service instructions.
-
Remove the protective cap and inspect the pressure connection.
-
Install the sensor using the specified sealing method and tightening torque.
-
Reconnect the electrical connector.
-
Test the current output and inspect for hydraulic leakage before returning the equipment to service.
Safety Notice: Hydraulic systems can retain high pressure after shutdown. Installation, pressure testing, and electrical checks should be performed by qualified maintenance personnel.
Frequently Asked Questions (FAQ)
Q1: What is the MBS1250 pressure transmitter used for?
The MBS1250 is an electronic pressure transmitter designed to measure pressure and provide an electrical output signal to a compatible monitoring or control system.
Q2: What is the measurement range of this sensor?
The illustrated 063G1857 configuration is labeled with a nominal measurement range of 0–400 bar, equivalent to 0–40 MPa.
Q3: What output signal does the sensor provide?
The product label specifies a 4–20 mA current output.
The receiving equipment must support this type of sensor signal.
Q4: What supply voltage does the sensor require?
The illustrated sensor label specifies an 8–30V DC supply voltage.
The correct wiring and supply requirements should be verified before installation.
Q5: Is MBS1250 a pressure sensor or a pressure switch?
The MBS1250 configuration shown is a pressure transmitter providing a proportional 4–20 mA signal.
It should not be treated as a simple on/off pressure switch unless the specific component specifications confirm that function.
Q6: Are 30B0506 and 063G1857 interchangeable?
These are provided as product reference numbers. Their exact relationship and interchangeability should be verified using the original sensor label, manufacturer documentation, and technical specifications.
Q7: Is this an original Danfoss pressure sensor?
This listing is offered through JISION. Original Danf