Relay Fuse Box Assembly with Wiring Harness for Komatsu PC120-8 PC200-8 PC200LC-8 PC210-8 PC210LC-8 Excavator | JISION
Relay Fuse Box Assembly with Wiring Harness for Komatsu PC120-8 PC200-8 PC200LC-8 PC210-8 PC210LC-8 Excavator Product Name: Excavator Relay Fuse Box Assembly Alternative Names: Fuse Box Assembly / Fuse Holder / Fuse Panel / Electrical Distribution Box / Fuse Block Assembly / Excavator Fuse Box with ...
Komatsu PC200-8 relay fuse box
,Excavator wiring harness assembly
,PC120-8 fuse box replacement
Product Name: Excavator Relay Fuse Box Assembly
Alternative Names: Fuse Box Assembly / Fuse Holder / Fuse Panel / Electrical Distribution Box / Fuse Block Assembly / Excavator Fuse Box with Wiring Harness
Referenced Excavator Models: Komatsu PC120-8 / PC200-8 / PC200LC-8 / PC210-8 / PC210LC-8
Product Brand: JISION
The JISION Relay Fuse Box Assembly is an aftermarket replacement electrical distribution component offered for selected Komatsu PC-series hydraulic excavators, including PC120-8, PC200-8, PC200LC-8, PC210-8, and PC210LC-8 reference applications.
Also known as an Excavator Fuse Box, Fuse Holder Assembly, Electrical Fuse Panel, or Fuse Distribution Block, this component is intended for use in compatible construction machinery electrical systems.
Fuse boxes play an important role in excavator electrical protection and power distribution. They provide designated locations for electrical fuses, helping protect individual machine circuits against excessive current caused by overloads or short circuits.
The illustrated product features a black rectangular plastic housing, multiple blade-type automotive fuses, two rows of fuse positions, and a set of colored electrical wires.
The visible fuse assembly includes red, yellow, green, and orange fuse bodies, allowing different rated fuses to be distinguished by color according to the applicable fuse standard.
The rear side of the product shows multiple electrical wire connections arranged within the black fuse holder structure.
The wiring includes various colored conductors intended for connection to the corresponding excavator electrical circuit.
In compatible Komatsu excavator configurations, fuse circuits may support electrical systems such as machine controllers, lighting, operator cabin accessories, solenoid valve power supplies, and other designated electrical equipment.
The exact circuit arrangement depends on the machine model, production serial number, electrical wiring configuration, and fuse box version.
The JISION Excavator Relay Fuse Box Assembly is offered as a replacement sourcing option for equipment electrical maintenance, fuse holder replacement, and wiring system repair.
JISION supplies aftermarket excavator fuse boxes, wiring harnesses, electrical connectors, relays, ECU controllers, sensors, switches, monitor panels, and construction machinery replacement parts for machinery repair workshops, equipment dealers, maintenance companies, and international wholesale distributors.
| Item | Description |
|---|---|
| Brand | JISION |
| Product Name | Excavator Relay Fuse Box Assembly |
| Alternative Product Name | Fuse Holder / Fuse Block / Fuse Panel |
| Product Type | Electrical Fuse Distribution Assembly |
| Product Category | Excavator Electrical & Wiring Parts |
| Original Equipment Reference | Komatsu |
| Main Referenced Models | PC200-8 / PC200LC-8 |
| Additional Referenced Models | PC120-8 / PC210-8 / PC210LC-8 |
| Equipment Type | Hydraulic Excavator |
| Housing Color | Black |
| Housing Material | Molded Plastic |
| Housing Shape | Rectangular |
| Fuse Type | Blade-Type Fuses |
| Fuse Arrangement | Two Rows in Illustrated Unit |
| Visible Fuse Colors | Red / Yellow / Green / Orange |
| Electrical Wiring | Attached Multi-Color Wires |
| Wire Colors | Red / Yellow / Blue / Green / White / Other Colors |
| Electrical Connection | Wired Fuse Holder Terminals |
| Mounting Structure | Integrated Housing Mounting Features |
| Main Function | Electrical Circuit Protection & Distribution |
| Fuse Ratings | Verify Against Original Circuit Specifications |
| Fuse Quantity | Confirm Actual Supplied Configuration |
| Relay Quantity | Confirm Separately |
| Operating Voltage | Confirm Machine Electrical Specifications |
| Wiring Configuration | Application-Specific |
| Product Condition | Confirm Supplied Version |
| Replacement Type | Aftermarket Replacement |
| Supply Type | Individual Unit / Wholesale Supply |
Technical Notice: The correct fuse ratings, electrical terminal arrangement, wire connections, fuse slot positions, and fuse box configuration must be verified against the original machine wiring diagram before installation.
The fuse box provides individual fuse positions for designated machine electrical circuits.
Correctly rated fuses are intended to interrupt excessive current when circuit conditions exceed their specified limits.
The fuse block organizes electrical connections for designated excavator systems.
It supports the distribution of electrical power to corresponding protected circuits according to the original machine wiring configuration.
The illustrated product features two rows of blade-type fuse positions.
The arrangement provides separate fuse locations for multiple electrical circuits.
The illustrated fuse assembly includes several fuse colors.
Different fuse colors are commonly used to distinguish fuse ratings.
Important: Fuse color must not be used as the only identification method. Always verify the printed amperage value and original machine wiring diagram.
The product includes multiple colored electrical wires extending from the rear side of the fuse holder.
These provide electrical connection points for integration into the matching excavator wiring system.
The fuse box features a black plastic housing with organized terminal cavities and fuse positions.
The enclosed structural design helps position electrical terminals and fuses within the assembly.
The blade-fuse arrangement allows individual compatible fuses to be removed and replaced when required.
The electrical supply must be isolated before servicing the fuse box.
Different Komatsu excavator models and production configurations may use different fuse layouts and wiring arrangements.
Matching the original fuse box structure is important for correct electrical circuit protection.
The JISION fuse box provides a replacement sourcing option when the original fuse holder has damaged terminals, deteriorated connections, or other diagnosed faults.
JISION provides fuse boxes, wiring harnesses, electrical connectors, and related excavator spare parts for international wholesale buyers, machinery dealers, and repair companies.
-
Komatsu PC200-8 Excavator
-
Komatsu PC200LC-8 Excavator
-
Komatsu PC210-8 Excavator
-
Komatsu PC210LC-8 Excavator
-
Komatsu PC120-8 Excavator
-
Selected Komatsu PC-8 Series Excavators
Important: The listed equipment models are aftermarket reference applications. Fuse box design, terminal position, wiring arrangement, and fuse ratings may vary between machines.
Before purchasing, please verify:
-
Excavator Model
-
Machine Serial Number
-
Original Fuse Box Part Number
-
Fuse Box Housing Shape
-
Number of Fuse Positions
-
Fuse Slot Arrangement
-
Fuse Type and Amperage Ratings
-
Electrical Wire Colors
-
Wiring Terminal Arrangement
-
Cable Length
-
Mounting Dimensions
-
Original Wiring Diagram
-
Original Product Photographs
Matching the excavator model or external fuse box appearance alone does not guarantee direct replacement compatibility.
The Komatsu PC-Series Relay Fuse Box Assembly is offered for compatible excavator electrical system maintenance and replacement.
Typical applications include:
-
Excavator Fuse Box Replacement
-
Electrical Fuse Holder Replacement
-
Fuse Distribution Panel Repair
-
Excavator Wiring Harness Maintenance
-
Machine Electrical Circuit Protection
-
Electrical Power Distribution Repair
-
Construction Machinery Electrical System Maintenance
-
Excavator Operator Cabin Electrical Repair
-
Fuse Terminal Replacement
-
Heavy Equipment Electrical Troubleshooting
The circuits protected by the fuse box depend on the original equipment wiring design.
A damaged fuse box or related electrical system may contribute to:
-
Repeatedly Blown Fuses
-
Loose Fuse Connections
-
Damaged Fuse Terminals
-
Corroded Electrical Contacts
-
Intermittent Power Supply
-
Certain Electrical Components Not Operating
-
Overheated Fuse Holder Connections
-
Damaged Electrical Wires
-
Intermittent Lighting or Accessories
-
Electrical Distribution Circuit Faults
Important: A repeatedly blown fuse may indicate an electrical short circuit, overloaded component, damaged wiring harness, or other system fault.
The underlying cause must be identified and corrected before fuse replacement.
Never install a fuse with a higher amperage rating than the equipment manufacturer specifies.
JISION supplies aftermarket electrical, electronic, hydraulic, and diesel engine replacement components for excavators and heavy construction machinery.
Our product range includes:
-
Excavator Relay Fuse Boxes
-
Fuse Holder Assemblies
-
Blade-Type Fuse Panels
-
Excavator Wiring Harnesses
-
Engine Wiring Harnesses
-
Electrical Connectors
-
Excavator Relay Assemblies
-
ECU Electronic Controllers
-
ECM Computer Boards
-
Excavator Monitor Panels
-
Excavator Switch Assemblies
-
Engine Oil Pressure Sensors
-
Engine Speed Sensors
-
Hydraulic Pressure Sensors
-
Hydraulic Solenoid Valves
-
Construction Machinery Electrical Accessories
JISION welcomes inquiries from excavator spare parts distributors, machinery repair workshops, construction equipment maintenance companies, equipment dealers, and international wholesale buyers.
Our team can assist customers with matching the required fuse box using original part numbers, excavator models, machine serial numbers, fuse configurations, and product photographs.
JISION provides spare parts sourcing assistance, quotation support, and export order coordination for international construction machinery replacement parts buyers.
-
Verify the original fuse box part number and configuration.
-
Confirm the Komatsu excavator model and machine serial number.
-
Compare the replacement fuse arrangement with the original unit.
-
Verify each required fuse amperage using the original wiring diagram.
-
Check the electrical wire colors and terminal positions.
-
Confirm the mounting structure and cable lengths.
-
Shut down the excavator and follow the manufacturer's electrical isolation procedures.
-
Disconnect the battery supply according to the service manual.
-
Inspect the original fuse box and electrical wiring for damage.
-
Disconnect the existing fuse box connections carefully.
-
Remove the original assembly according to the service instructions.
-
Install the correctly matched replacement fuse holder.
-
Connect each wire to the correct electrical circuit according to the wiring diagram.
-
Install only the manufacturer-specified fuse types and ratings.
-
Reconnect the electrical power supply using the prescribed service procedure.
-
Test the designated electrical circuits and verify normal operation.
Safety Notice: Excavator fuse box installation and wiring work should be performed by qualified machinery electrical maintenance personnel.
Incorrect wiring, excessive fuse ratings, or poor electrical connections may lead to equipment damage, overheating, or fire.
A fuse box provides designated fuse locations for protecting electrical circuits against excessive current.
Depending on the assembly design, it may also be part of an electrical distribution system that includes relay-controlled circuits.
PC200-8 is a common aftermarket reference application for this type of fuse box.
Exact compatibility must be confirmed using the original fuse box configuration and machine serial number.
PC200LC-8 appears in aftermarket supplier listings for related fuse box assemblies.
The fuse layout and electrical wiring must be checked before ordering.
These models are listed in aftermarket application references.
The correct replacement configuration must be verified against the original machine.
PC120-8 appears in selected aftermarket product listings.
Compatibility depends on the original electrical system and fuse holder design.
The illustrated product features multiple colored electrical wires connected to the rear side of the fuse box.
The actual supplied cable lengths and termination style should be confirmed before ordering.
Blade fuses are visible in the supplied product photographs.
The actual fuse quantity, ratings, and included accessories must be confirmed with the sales team.
Although the product category may be described as a relay fuse box assembly, separate relays are not visible in the supplied photographs.
Please confirm whether relays are included in the actual package.
The correct ratings depend on the protected circuits and original equipment design.
Always follow the machine service manual and electrical wiring diagram.
No. Installing a fuse with a higher rating than specified can compromise electrical circuit protection.
The cause of repeated fuse failure should be diagnosed before replacement.
This listing describes an aftermarket replacement offered by JISION. Original Komatsu manufacturing is not claimed unless documented for the specific supplied product.
Yes. JISION welcomes wholesale inquiries from excavator spare parts distributors, repair workshops, machinery dealers, and international importers.
Contact JISION for fuse box identification, electrical configuration matching assistance, product specifications, stock information, and wholesale quotations.
Please Provide:
-
Required Product: Relay Fuse Box Assembly
-
Excavator Model: PC120-8 / PC200-8 / PC200LC-8 / PC210-8 / PC210LC-8
-
Machine Serial Number
-
Original Fuse Box Part Number, If Available
-
Original Fuse Box Front and Rear Photographs
-
Fuse Slot Quantity and Arrangement
-
Electrical Wire Configuration
-
Required Quantity
-
Destination Country
Our sales team can assist with replacement fuse box identification and quotation information.
JISION – Your Reliable Partner for Excavator Electrical Parts & Construction Machinery Spare Parts.